Continuous monitoring
Temperature, humidity, ammonia, CO₂, light intensity, leaf moisture and air flow – refreshed every few seconds and colour-coded Normal / Warning / Critical.
Keep every rearing house in the silkworm comfort zone – day and night. Sense, automate and control from your phone, with alerts before a bad hour becomes a lost batch.
Concept demo – all readings on this site are simulated; no real device is connected.
Click any sensor node or equipment actuator inside the rearing shed below to see how the Thartek controller protects silkworm health in real time.
Silkworms are sensitive: a few hours of heat, stale air or low humidity can hurt leaf intake, growth and cocoon quality. The Sericulture IoT Controller measures the room, switches your equipment automatically, and tells you the moment something needs a human.
Temperature, humidity, ammonia, CO₂, light intensity, leaf moisture and air flow – refreshed every few seconds and colour-coded Normal / Warning / Critical.
Simple IF-THEN rules drive the heater, exhaust fan, humidifier and misting pump – with hysteresis so relays do not chatter.
Check readings, flip a relay or return to automatic from the mobile app. Critical events trigger an alert to the owner.
Fewer night-time surprises, less manual checking across multiple sheds, and a logged history of what happened and who changed what.
The farmer is in charge. Any relay can be taken off automation instantly and handed back with one tap.
Designed and prototyped by Thartek Innovations, Tenkasi – for rural farms with patchy mobile networks and real-world conditions.
A Thartek technician mounts the controller in the rearing house, fits the sensor probes at bed height and mid-room, and wires the four relay outputs to the heater, exhaust fan, humidifier and misting pump.
The device is registered to the owner’s account, mobile network is verified, and threshold bands are set for the rearing stage. Each relay is set to Automatic or Manual.
Probes continuously report temperature, humidity, ammonia, CO₂, light and leaf moisture; air flow status is derived from the ventilation state. Values are sampled every few seconds.
Readings are sent over the mobile network (MQTT-style messages) to the cloud, then shown live on the web dashboard and the mobile app, with a trend history.
Automation rules are evaluated locally against the thresholds. When a threshold is crossed the matching relay switches, and the event is logged.
Critical readings raise an alert to the owner. At any time the owner can override a relay manually; automation for that relay is suspended until it is returned to Automatic.
| Parameter | Why it matters | Demo default band | Equipment it can drive |
|---|---|---|---|
| Temperature | Drives growth rate and disease risk | 24–28 °C normal | Heater, Exhaust Fan |
| Humidity | Affects leaf freshness and worm health | 70–85 % normal | Humidifier, Exhaust Fan |
| Ammonia (NH₃) | Builds up from bed litter; harmful to worms | ≤ 10 ppm normal | Exhaust Fan |
| CO₂ | Indicator of poor ventilation | ≤ 1000 ppm normal | Exhaust Fan |
| Light intensity | Strong direct light disturbs rearing | ≤ 600 lux normal | Alert only |
| Leaf / moisture level | Fresh, moist mulberry leaf improves feeding | 70–92 % normal | Misting Pump |
| Air flow | Confirms ventilation is actually working | ≥ 0.12 m/s good | Exhaust Fan |
Bands shown are demonstration defaults, not agronomic recommendations. In a real deployment they would be configured per customer and rearing stage.
Each of the four relays has its own mode. In Automatic the rules decide; in Manual the farmer decides and the rules for that relay are suspended.
Rules use hysteresis (e.g. fan ON above 28 °C, OFF at 27 °C) to avoid rapid relay chatter.
Override is per relay: taking the Exhaust Fan off automation does not affect the Heater, Humidifier or Pump.
The phone on the right is live – its values are driven by the same simulator as the dashboard.
Explore the full dashboardLog in with the demo credentials to explore five simulated customer devices across Tamil Nadu – live sensor values, relay control and automation rules.
admin12345